|
|
KUIO30 Series Features Open Frame Package
Our KUIO30 series of AC-DC power supplies integrates 3,000 Vac reinforced insulation, low leakage current and low standby power. With an adjustable output voltage and internal EN55022 Class B Filter, this series is housed in a 3.34 x 1.36 x 0.77-inch open frame package and includes overvoltage, overcurrent and short circuit protection. These Class 2 devices also meet UL /EN /IEC60950-1, RoHS and REACH standards.
|
|
|
|
|
|
|
|
|
Initial Set Voltage Accuracy Percent (%)
|
|
-1.0 Min., 1.0 Max. 230 Vac and full load
|
|
Line Regulation Percent (%)
|
|
-0.2 Min., 0.2 Max. Low line to high line at full load
|
|
Load Regulation Percent (%)
|
|
- -0.7 Min., 0.7 Max. No load to full load, 3.3 Vout, 5 Vout
- -0.5 Min., 0.5 Max. Others
- -0.6 Min., 0.6 Max. 10% load to 90% load, 3.3 Vout, 5 Vout
- -0.4 Min., 0.4 Max. Others
|
|
Minimum Voltage Adjustability
|
|
-10 %
|
|
Maximum Voltage Adjustability
|
|
10 %
|
|
Typical Maximum Load
|
|
0 %
|
|
Ripple and Noise (mVp-p)1
|
|
- 50 Typ. With a 10µF/25V 1206 X7R MLCC, 3.3 Vout, 5 Vout, 7.5 Vout, 9 Vout
- 50 Typ. With a 1µF/50V 1206 X7R MLCC, 12 Vout, 15 Vout, 18 Vout, 24 Vout, 28 Vout, 36 Vout
- 50 Typ. With a 0.1µF/100V 1206 X7R MLCC, 48 Vout, 53 Vout
|
|
Transient Response
|
|
- 5% Vout Max. Load step from 50-75% change at 2.5A/µs, peak deviation
- 500µs Typ. Recovery time
|
|
Over Voltage Protection Percent (%)
|
|
125 Min., 140 Max. % of Vout (nom); Automatic recovery
|
|
Over Load Protection Percent (%)
|
|
140 Typ. % of lout rated; Hiccup mode
|
|
Short Circuit Protection
|
|
Continuous Automatic Recovery
|
|
1 Measured by 20MHz bandwidth
|
|
|
|
|
General Specifications
|
|
- Isolation voltage, Vac: 1 minute, reinforced insulation Input to output 3000 Min.
- Isolation resistance, GΩ: 500 Vdc 0.1 Min.
- Switching frequency, kHz: 230 Vac Full load 30 Min. 45 Typ. 60 Max.
|
|
Environmental Specifications
|
|
- Operating ambient temperature, ºC
- Natural convection With derating -40 Min. +85 Max
- Storage temperature range, ºC
- Operating altitude, M
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6
- Relative humidity: Non-condensing 5% to 95% RH
|
|
Physical Specifications
|
|
- Design meet safety standard: IEC/EN/UL 60950-1, 62368-1, UL:E193009, CB:UL (Demko)
- Dimensions
- 3.34 x 1.36 x 0.77 inches (84.83 x 34.54 x 19.56 mm)
- Weight
- Connector type 60.5g (2.13oz)
- Pin type 58g (2.05oz)
- MTBF: 3.341 × 106 hrs, MIL-HDBK-217F, Full load
|
|
EMC Specifications
|
|
- EMI: EN55011,EN55022 and FCC Part 15, Conducted Class B, Radiated, Class B
- Harmonic currents: EN61000-3-2 Full Load, Class A
- Voltage flicker: EN61000-3-3
- EMS: EN55024
- ESD: EN61000-4-2, Air ± 15kV and Contact ± 8kV, Perf. Criteria A
- Radiated immunity: EN61000-4-3, 20 V/m, Perf. Criteria A
- Fast transient: EN61000-4-4, ±2kV, Perf. Criteria A
- Surge: EN61000-4-5, DM ±1kV, Perf. Criteria A
- Conducted immunity: EN61000-4-6, 20 Vr.m.s, Perf. Criteria A
- Power frequency magnetic field: EN61000-4-8, 30 A/m, Perf. Criteria A
- Dip and interruptions: EN61000-4-11, Perf. Criteria A
- Damped oscillatory wave: EN61000-4-18, DM ±1kV and CM ±2.5kV, Perf. Criteria A
|
|
|
|
|
|
|
|
|